The instruments and equipment used for testing (including specialized equipment) should be verified or calibrated and within their validity period, and the accompanying testing equipment should be inspected and qualified. The testing instruments used should meet the
expected usage requirements, and their measurement uncertainty or maximum allowable error should be less than one-third of the allowable error of the measured parameter. The testing equipment and instruments used are as follows:
a) Wind field simulation system: The wind speed adjustment range should be at least 0m/s~25m/s, and the accuracy should be 1m/s1
b) Flight accuracy measurement system: used to measure the position and angle changes of unmanned aerial vehicle systems during flight, and the horizontal measurement accuracy should be
10 cm, The vertical measurement accuracy should be 15cm, the angle measurement accuracy should be 1, and the measurement interval time should be 0.5s; c) Timer: The measurement accuracy should be 0.1s