Equipment workflow
Sample installation: Fix 6 PTC samples to the fixture, connect electrical terminals, and attach thermocouples;
Parameter settings: Touch screen settings: test voltage, time for each stage, target cycle count, power/temperature failure threshold;
Start up test: 6 stations can be started individually/fully;
Automatic loop operation, real-time display of each workstation: current count, (heating/fan voltage, heating/fan current, heating/fan power, heating temperature, etc.);
The workstation reaches the set number of times → the workstation automatically stops and marks "test completed";
Workstation failure → The workstation cuts off the output, locks it, records the failure data, and continues with other workstations;
Complete all workstations or manually stop, save all test records, and export test reports.
Failure types: open circuit, short circuit, power drop, overtemperature, leakage over limit;
The upper computer stores test logs and supports exporting Excel reports;
Hardware dual layer security: software protection+independent hardware circuit fuses, leakage protection, emergency stop.