Constant temperature and pressure water supply: 5 water tanks, storage tank, soft water tank, 1 15-30 ° C water tank, and 4 30-60 ° C water tanks. The water temperature can be adjusted within a range with a deviation of ± 2 ° Water tank temperature and level control, with minimum and maximum water level alarms. The system can display the water level situation. The water temperature is controlled by the heating and cooling system and is connected in parallel with the water level, so it will not decrease due to water replenishment. The water temperature deviation is within ± 2 °.
1-1 Cooling capacity: The cold water tank cools the cold water from 30 ℃ to 15 ℃ for a total time of ≤ 1 hour
1-2 Heating capacity: 1000L of cold water in the cold water tank is heated from 15 ℃ to 30 ℃ in no more than 1 hour; 1000L of hot water in the hot water tank is heated from 20 ℃ to 60 ℃ in no more than 1 hour. Heating capacity: 1000L of cold water in the cold water tank is heated from 15 ℃ to 30 ℃ in no more than 1 hour; 1000L of hot water in the hot water tank is heated from 20 ℃ to 60 ℃ in no more than 1 hour
1-3 four temperature controlled water tanks, with adjustable water pressure ranging from 0-0.35Mpa and stable water pressure of ± 0.02Mpa.
The water supply pressure can be adjusted within the range of 0-4 MPa
1-5 1T soft water device, adjustable water hardness (20~300) ppm, automatically adds additives or water supply ratio after setting the value, and the system displays water hardness in real time.
The 1-6 overall water supply system is connected by PPR pipes, and the water pump joint is connected by a hose.
1-7 Each workstation is equipped with water pipes, cold water pipes (switching between two water tanks), hot water pipes (switching between two water tanks), and system control switching
During the 1-8 energy efficiency test, 5 stations were connected to cold and hot water flow meters. Two high-precision small range flow meters will be added to detect the water consumption of the drum condensation valve
Titration equipment:
PH meter, measuring range 0.00... 14.00 pH, resolution 0.01 pH, measurement accuracy not less than ± 0.05 pH value;
A water hardness tester with a measurement range of 0.05... 200 is easier to measure per liter. The measurement error is not less than ± 2%;
Automatic titration: a microprocessor controlled titrator. Dropper size 10ml, division 0.01 ml, minimum deposition rate below 25 µ m/min;
Water conductivity meter with a measurement range of 0-20000 µ S/cm. Resolution of 0.001 µ S/cm. The measurement accuracy shall not be less than ± 0.05+0.025 * average value.