Test items:
1. Rated thermal load and thermal efficiency;
2. Temperature rise of water heater;
3. Temperature rise when water is stopped;
4. Heating time;
5. Water temperature adjustment range;
6. Hot water stabilization time;
7. Water temperature fluctuation;
8. Withstand voltage test
Technical Parameters:
1. Hot water flow rate: 0-30L/min, accuracy: 0.5%F.S;
2. Water inlet pressure: 0~1.6MPa, accuracy: 0.5%F.S;
3. Inlet water temperature: 0-100℃, accuracy: 0.5%F.S;
4. Outlet water temperature: 0-100℃, accuracy: 0.5%F.S;
5. Gas flow: 0-5m3/H, accuracy: 1%F.S;
6. Gas temperature: 0-50℃, accuracy: 0.5%F.S;
7. Gas humidity: 0-RH, accuracy: 2%F.S;
8. Gas flow meter pressure: 0-10KPa, accuracy: 0.5%F.S;
9. Primary gas pressure: 0-10KPa, accuracy: 0.5%F.S;
10. Secondary gas pressure: 0-5KPa, accuracy: 0.5%F.S;
11. Wind pressure: 0-1000Pa, accuracy: 0.5%F.S;
12. Atmospheric pressure: 0-120KPa, accuracy: 1%F.S;
13. Voltage: 0-300V, accuracy: 1%F.S;
14. Current: 0-1A, accuracy: 1%F.S.