Test pressure: 0.05~60MPa;
Opening frequency: 8-15 times/min, 10S±2S/or 2 times/min;
Opening and closing stroke: ≤4 laps (can be set);
Test times: ≮1 million times;
Test medium: air or nitrogen; (please consult for special medium)
Test environment temperature: normal temperature or -50~150℃; (please consult for special temperature requirements);
Temperature fluctuation: ±1℃;
Temperature uniformity: ≤±2℃;
System output torque: 20N.M;
Test station: 1~5 station;
Torque control accuracy: ±0.3N.M;
Torque measurement accuracy: ±0.5%F.S;
Driving air: 0.6MPa≤P≤0.8MPa;
Power requirements: AC380V50Hz;
Control method: automatic.
Functions and features:
·The control element adopts servo motor and imported torque sensor to control the opening and closing of the valve, with small inertial impact and stable control;
·Using a computer to control the test process, real-time display of pressure-time curve, test pressure and other values, test results can be automatically saved or printed out, and the test results can be automatically saved after power off;
·Computer data acquisition and processing, print out environment/medium temperature, cycle times and cycle pressure waveform;
·The opening and closing torque stroke of the cylinder valve can be set;
·The number of operating cycles can be set freely during the test, and the test can be automatically stopped when the requirements are met;
·With power failure protection function, the system will automatically relieve pressure after power failure and terminate the test to ensure the safety of operators and equipment to the limit;
·The test piece leakage can be set as the alarm point. When the leakage reaches a certain level, the system will automatically alarm and stop working, and the computer will remain powered.