GB-T-30306-2013 internal cores for domestic and similar drinking water treatment GB 30307-2013 domestic and similar drinking water treatment plant QB reverse osmosis purified water for domestic and similar uses
Product description:
according to the relevant standards, the equipment meets the requirements of water purifier, water and other products for static pressure, water pulse and other tests, a special testing machine for pulse fatigue test of test products under water pressure of 0.1-1.2 mpa. It is often used to test whether the voltage withstand test, pulse test and other tests meet the design requirements. The testing machine is controlled by PLC/IPC, and the relevant tests are completed by setting and controlling the relevant parameters.
Pulse pressure: 1 ~ 2.5 mpa
2. Pressure driving mode: water pump frequency conversion/air pump pressure
3. Pressure accuracy: 0.1
4. The higrate of boost pressure: not less than 0.2 mpa/s
5, constant pressure time: 1-99999s
6, Cycle Pressure: 0.1-2.5 mpa ca
7、 Cycle Frequency: 6-30 times/min8、 cycle number: 200,000 times/Test (can be set)
8. test number: 1 Way, (maximum extend 5 station)
9.Water temperature controllable range:
10.10 ~ 24 degrees control accuracy, plus or minus 2 degrees (optional)
11. test media: tap water
12.control screen: 7 inches, 17 inches optional (with data export function)(optional)
13.Water: tap water, gas: not less than 0.6 mpa
14. power: 220V 50HZ 2.5 kw
15.equipment size: 1850X750X1650MM