QXYL system air tightness testing equipment is the use of air tightness testing and automatic testing combined, according to customer requirements can be customized, the internal testing module using the company's own leak detector. The test bench is controlled by PLC and operated by touch screen in Chinese, the product is fastened and clamped by pneumatic principle, and the high precision pressure transmitter is used to detect the constant pressure and fluctuation of the internal pressure of the product. The device has the function of automatic judgment and alarm. Ok-qualified, NG-unqualified and sound and light alarm system operation is simple, the accessories used by imported and domestic well-known brands, stable and reliable work. Scope of application: Production Line Sealing Test, laboratory sealing test and other common industries. Can be customized according to customer samples and related requirements.
Technical parameters:
1, station number: single station (up to 8 stations can be ordered)
2, pressure test range: 0.01-0.6 mpa, test pressure accuracy: 0.1/0.25/0.5 level
3, pressure holding time: 1s-99999S adjustable
4, pressure mode: 01: direct pressure Type 02: differential pressure Type 03: Vacuum Type
5, mechanical/Mitsubishi PLC Control
6, using single-phase power supply with ground wire: AC220V ± 10% , 50Hz 0.5 KW
7, equipment size: 300X 420x 250 units: MM
8, Tempo: about 400 beats per hour