It is mainly used for the high temperature and high humidity aging test of the whole intelligent toilet, in order to test the toilet/toilet in the high temperature and high humidity environment for a long time, so as to judge and test the quality reliability, the lab controls the temperature and humidity of the environment by PLC control and monitors the electrical parameters of the products and records the test data.
Related parameters:
1.Room size: according to the user to provide space
2.Humidity range: 90% -98% RH Temperature: RT + 10-85 °C
3.Humidity control accuracy:Plus or minus 2%
4.Humidity uniformity: plus or minus 2%
5.Control mode: PLC and PID
6.Ventilation: automatic ventilation
7.Humidification: ultrasonic high-temperature humidification
8.Voltage: 0-300V adjustable
9.Test station: 0-20
10.Temperature Detection: Type K
11.Power supply: 380V 20KW