Executive standards: QB/T 4697-2014 (special pressure pump), QB/T 4144-2010 (reverse osmosis water purifier)
1. Basic operating condition durability (core lifespan)
1. Start-stop cycle life (under standard operating conditions)
- Cycle: Operate for 10 seconds → Stop for 5 seconds, accumulating ≥100,000 cycles
- Load: Outlet pressure 0.42±0.042 MPa, inlet pressure 0.1 MPa
- Judgment: No jamming, leakage, abnormal noise, or performance degradation
2. Continuous and durable operation
- Continuous operation for ≥2000 hours under rated voltage and rated pressure
- High and low voltage limits: 110% rated voltage for 24 hours continuously; 90% rated voltage in cycles (7.5 minutes on/2.5 minutes off)
II. Electrical performance monitoring (full-process acquisition)
- Operating current, voltage, power, insulation resistance, temperature rise
- Judgment: Current fluctuation ≤±10%; no short circuit, overheating, or insulation failure
III. Hydraulic performance attenuation test
- Real-time monitoring: flow rate, head (outlet pressure), rotational speed
- Comparison: performance degradation rate before and after testing (requirement: ≤5%)
IV. Sealing and mechanical reliability
- Leak detection: No leakage/dripping from the shell, shaft seal, or joints
- Mechanical strength: vibration, water hammer impact, shell pressure resistance