1. The detection platform is used in conjunction with constant pressure water supply. It outputs a constant test water pressure to the pipeline through an external variable frequency constant pressure water supply, and uses a manual pressure regulating valve for pressure relief and reflux. Each workstation is equipped with independent pressure gauges and electrical parameter displays, and is powered by variable frequency electricity and mains electricity.
2. The testing platform is divided into three main outputs, which can be switched between three different types of testing water through a switch. Constant temperature water/proportioned water/pure water and other independent pipeline outputs can be switched and used by users according to actual testing.
Standard testing conditions
-Environment: 25 ± 2 ℃, humidity 45%~75%
-Inlet water temperature: 25 ± 1 ℃, inlet pressure: 0.24 ± 0.02MPa
-Water quality: Hardness 250 ± 20mg/L, TDS 500 ± 50mg/L, pH 7.0~7.5
-Power supply: rated voltage ± 1%, 50 ± 1H